SL04 box connected with a LAN, and when using the MA2, how to fix fixture flashes sometimes
The maximum refresh rate of dmx512 is 44Hz, when sending Artnet data in MA2, if delay set to 0 ms, there no interval between packets, the maximum refresh rate of DMX512 will be exceeded, causing the lights to flicker occasionally. solution: In the Artnet settings, the delay time is set to at least 1ms. This […]